<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-06 02-56-34
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
107.80 MHz 5/5, 53 dBuV P2 SR
Pilot RDS Phase Difference
7.3 kHz 5.8 kHz 0 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
14 kHz 24 kHz 19057 0,0052
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-5,9 dBr -3,02 dBr -1,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"P2 SR " E402 14 (Classics) 0 1 1 9 1:56, 6.12.2024
RT
"Notturno P2 "
AF EON
88.5, 88.8, 90.7, 91.5, 91.7, 92.3, 92.6, 92.7, 93.6, 94.5, 95.3, 95.5, 95.7, 97.5, 98.6, 98.9, 99.2 MHz E224, E201, 5220, E203
FM Scope Max at: 24 kHz MIN: 14 kHz % above 76 kHz: 0,0052 Acquired: 2024/12/06 2.55.30 Total samples: 19057 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: -1,1 dBr MIN: -5,9 dBr AVE: -3,02 dBr % above 12,2 dBr: 0,0 Last value: -5,1 dBr (2024/12/06 2.55.30) 02.42 02.44 02.46 02.48 02.50 02.52 02.54 0 50 100 Dev. MAX [kHz] -6 -4 -2 0 Pm [dBr]